Legal Info

You are here: Products > Epoxy Bonded Glass> Technical Data Sheet  
    
    
    Epoxy Bonded Glass Filament Wound Cylinders and Tubes.
 
     Technical Data Sheet
 
SIZE
Type : CYL-50H & CYL-75
Dia  12 mm to 16 mm ID tubes upto 500 mm long (minimum wall thickness 3 mm)
Dia > 16 mm to 24 mm ID tubes upto 1000 mm long (minimum wall thickness 3 mm)
Dia > 24 mm to 50 mm ID tubes upto 1500 mm long (minimum wall thickness 3 mm)
Dia > 50 mm to 550 mm ID cylinders upto 2000 mm long (minimum wall thickness 3 mm)
Type : CYL-50C

Dia 550 mm to 2000 mm ID cylinders upto 3000 mm long (minimum wall thickness 5 mm)
AND ALL THE SIZES AS MENTIONED IN CYL-50H

Colour : Natural
PROPERTIES UNITS TEST METHOD AVERAGE TEST RESULTS
CYL-50H CYL-75 CYL-50C
Specific Gravity --- IS: 10192-1982 1.7 (Min) 1.7 (Min) 1.7 (Min)
Glass Content
 
% BS: 2782 70 (Min) 70 (Min) 65 (Min)
Water Absorption
 
% IS: 1998-1962 0.2 (Max) 0.2 (Max) 0.2 (Min)
Compression Strength 

Axial
Circumferential
 


MPa
MPa

ASTM D 695-80

80 (Min)
300 (Min)

110(Min)
110(Min)

80 (Min)
300 (Min)
Tensile Strength (Axial)
 
ASTM D 638-01 45 (Min) 130 (Min) 45 (Min)
Dielectric Strength in Oil at90°C (Proof voltage for 1 minute)
Axial 
Circumferential 
Radial 
O<5 mm Wall thickness 
  >5 mm Wall thickness
 



KV/25mm
KV/25mm

KV/mm
KV/mm



IS: 1998-1962



50 (Min)
50 (Min)

10 (Min)
7  (Min)



75 (Min)
75 (Min)

10 (Min)
7 (Min)



50 (Min)
50 (Min)

10 (Min)
7 (Min)
Dielectric Constant ---- ASTM D150-98 10 (Max) 10 (Max) 10 (Max)
Dissipation Factor ---- ASTM D150-98 0.025 (Max) 0.025 (Max) 0.025 (Max)
Insulation Resistance
 
Ohms IS: 1998-1962 10" (Min) 10" (Min) 10" (Min)
Comparative Tracking Index
 
---- IEC 112-79 300 (Min) 600 (Min) 300 (Min)
Marten Heat Distortion Temp.
 
°C IS: 1998-1962 155(Min)
Class F Insulation
155(Min)
Class F Insulation
90 (Min)
Class A Insulation
Copyright © 2003 Lamtuf Plastics Ltd. Site design - dristi.